Upload
degare-bidault
View
108
Download
1
Embed Size (px)
Citation preview
LES AMBIANCES LES AMBIANCES THERMIQUESTHERMIQUES
22 NOVEMBRE 2012
DR CH MAILLET CBE NAMUR
AMBIANCES THERMIQUESAMBIANCES THERMIQUES
• CHAMP D’APPLICATION• ANALYSE DES RISQUES ET PREVENTION• VALEURS D’ACTION• PROGRAMME DE MESURES ORG ET TECH• MESURES SI FROID EXCESSIF• MESURES SI CHALEUR EXCESSIVE• SURVEILLANCE DE SANTE• TRAVAILLEURS SENSIBLES• INFOS ET FORMATIONS
CHAMP ET DEFINITIONSCHAMP ET DEFINITIONS
• EMPLOYEURS ET TRAVAILLEURS/ LOI BE
• COMITE, DELEGATION, TRAVAILLEURS
ANALYSE DES RISQUES, ANALYSE DES RISQUES, FACTEURSFACTEURS
• TEMPERATURE DE L’AIR
• HUMIDITE RELATIVE EN %
• VITESSE DE L’AIR EN M/SEC
• RAYONNEMENT THERMIQUE
• CHARGE PHYSIQUE DE TRAVAIL
• METHODE DE TRAVAIL ET EQUIPEMENT T
• VT ET EPI
ANALYSE DES RISQUESANALYSE DES RISQUES
• FCT EVOLUTION DES FACTEURS
-PENDANT LA DUREE DU TRAVAIL
-SELON LA SAISON
-SELON LES CIRCONSTANCES DE TRAVAIL
MESURAGES SI NECESSAIRE
ANALYSE DES RISQUESANALYSE DES RISQUES• METHODE D’ANALYSE
• SELON AVIS SPPTS
• ACCORD DU COMITE
• SI DESACCORD, METHODES SPF
• MESURES DE PREVENTION
• ADAPTEES
• FCT DES VALEURS D’ACTION
• FCT NORMES CONFORT THERMIQUE
VALEURS D’ACTION FROIDVALEURS D’ACTION FROID
T° AIR NE PEUT ETRE INFERIEURE A:
•18° SI TRAVAIL TRES LEGER
•16° SI TRAVAIL LEGER
•14° SI TRAVAIL MOYEN
•12° SI TRAVAIL LOURD
•10° SI TRAVAIL TRES LOURD
VALEURS D’ACTION CHALEURVALEURS D’ACTION CHALEUR
T°AIR NE PEUT PAS DEPASSER :
•29° SI TRAVAIL LEGER OU TRES LEGER
•26° SI TRAVAIL MOYEN
•22° SI TRAVAIL LOURD
•18° SI TRAVAIL TRES LOURD
SELON INDICE WBGT FCT HUMIDITE, T° SECHE, VITESSE AIR, RAYONNEMENT
PROGRAMME DE MESURES (1)PROGRAMME DE MESURES (1)
• EN CAS DE DEPASSEMENTS VALEURS
PRENDRE DES MESURES TECHNIQUES ET ORGANISATIONNELLES- FACTEURS D’AMBIANCE- CHARGE DE TRAVAIL- METHODES DE TRAVAIL- DUREE ET INTENSITE DE L’EXPO
PROGRAMME DE MESURES (2)PROGRAMME DE MESURES (2)
• EN CAS DE DEPASSEMENTS VALEURS
PRENDRE DES MESURES TECHNIQUES ET ORGANISATIONNELLES
-ADAPTATION DES HORAIRES/PAUSES
-EQUIP PROTECTION INDIVIDUELS
-BOISSONS
EXEMPLES DE MESURES /CHALEUREXEMPLES DE MESURES /CHALEUR
ALTERNANCE TRAVAIL/PAUSESALTERNANCE TRAVAIL/PAUSES
PROTECTION=BONNE, SI APPLICATION
1.NORMES EN ISO NBN 7243/ 7933/ 9886
2.AUTRE ALTERNATIVE SUR AVIS MT
3.AUTRE SUR CONVENTION COLLECTIVE DE TRAVAIL, DE PROTECTION EQUIVALENTE A 1er POINT
4.MESURES DANS L’ANNEXE 1
5.DYNAMIQUES
ALTERNANCE TRAVAIL REPOSALTERNANCE TRAVAIL REPOSANNEXE 1 (ANNEXE 1 (article 6)article 6)
ALTERNANCE WBGT
TR LEGER TR MILOURD
TR LOURD TR TRES LOURD
45’TRAVAIL/15’REPOS
29,5° 27° 23° 19°
30’TRAVAIL/30’REPOS
30° 28° 24,5° 21°
PRESCRIPTIONS MINIMALES PRESCRIPTIONS MINIMALES FROIDFROID
1. FROID TECHNOLOGIQUE (EX FRIGO)
- VT ET EPI (EQUIP PROT INDIVIDUEL)
- BAISSE VITESSE AIR
- SECHAGE VETEMENT DE TRAVAIL(VT)
- BOISSONS CHAUDES
- PAUSES AU CHAUD
PRESCRIPTIONS MINIMALES PRESCRIPTIONS MINIMALES FROID FROID
2. FROID CLIMATIQUE (1)
DU 1/11 AU 31/3, DANS DES LIEUX OUVERTS OU EXTERIEURS (EX CHANTIER)-DISPOSITIFS DE CHAUFFAGE PRESENTS-SI T°<5°: MISE EN MARCHE-PAUSES EN LOCAL CHAUFFE, AVEC ACCORD SYNDICAL
MESURES FROIDMESURES FROID
TRES DECONSEILLE
TRAVAIL AU FROIDTRAVAIL AU FROID
PRESCRIPTIONS MINIMALES PRESCRIPTIONS MINIMALES FROIDFROID
2. FROID CLIMATIQUE (2)
DU 1/11 AU 31/3, DANS LES COMPTOIRS EXTERIEURS DE COMMERCE DE DETAIL-SI T°<5°: INTERDICTION DE TRAVAIL-SI 5°<T°<10°, CHAUFFAGE PUISSANT OU PAUSE EN LOCAL CHAUFFE-PLANCHER ET TOIT-INTERDIT ENTRE 19H ET 8H, >2H SANS PAUSE 1H, >4H/JOUR
COMPTOIRS EXTERIEURSCOMPTOIRS EXTERIEURS
MESURES PROTECTION CHALEURMESURES PROTECTION CHALEUR
1. ORIGINE TECHNOLOGIQUE (EX FONDERIE)
SI DEPASSEMENT DES VALEURS,
-AVEC CONVECTION: DISPOSITIFS DE VENTILATION ARTIFICIELLE, ASPIRATION
-AVEC RAYONNEMENTS (EX METAL):
ECRANS, VT, EPI
BAISSE DE LA DUREE D’EXPOSITION
PAUSES AU FRAIS (SALLE DE RECUP)
BOISSONS FRAICHES/AVIS MT
TRAVAIL AU CHAUDTRAVAIL AU CHAUD
TRAVAUX AU CHAUDTRAVAUX AU CHAUD
MESURES CHALEURMESURES CHALEUR
2. ORIGINE CLIMATIQUE(DEHORS ET DEDANS)
SI DEPASSEMENT DES VALEURS,
- DISPOSITIFS DE VENTILATION MONTES EN 48H-BAISSE DE LA DUREE D’EXPO-PAUSES AU FRAIS(SALLE RECUP)-BOISSONS FRAICHES/AVIS MT-ALTERNANCE TRAVAIL/REPOS (ANNEXE 1) SI PERSISTANCE DU PROBLEME
MESURES MESURES CHALEURCHALEUR
3. CHALEUR EXCESSIVE TECHN ET CLIMAT
-MEMES MESURES QUE POUR CHALEUR TECHN
-PROTECTION CONTRE LE RAYONNEMENT
4. INTERV PROGRAMMEES DE COURTE DUREE A CHALEUR +++ (EX CENTRALE, FOUR,…)-AVIS PREALABLE DU MT SUR EXPOSITION-SURVEILLANCE DE SANTE INSTANTANEE POSSIBLE
AMBIANCES DE TRAVAIL TRANSPORTAMBIANCES DE TRAVAIL TRANSPORT
SURVEILLANCE DE SANTESURVEILLANCE DE SANTE
1.TRAV EXPOSES REGULIERMENT, TECHNOLOGIQUEMENT AU-FROID: T°<8°
- CHALEUR: >VALEURS ACTION
2.TRAV PRESTANT A L’EXTERIEUR
SURVEILLANCE PREALABLE ET ANNUELLE
TRAVAIL AU CHAUDTRAVAIL AU CHAUD
CHARGE DE TRAVAILCHARGE DE TRAVAIL
CHANTIER AU CHAUDCHANTIER AU CHAUD
SENSIBILITES PARTICULIERESSENSIBILITES PARTICULIERES
- MATERNITE,JEUNES, VIEUX
- MALADIES COMME HYPO ET HYPERTHYROIDIE, MAIGREUR, OBESITE, PROBLEMES DE STABILISATION DE T°, DE TA, PROBLEMES CIRCULATOIRES (VARICES, RAYNAUD..)
MESURES SPECIFIQUES SUR AVIS DU MEDECIN DU TRAVAIL
INFO FORMATIONINFO FORMATION
• ANALYSE RISQUES ET GESTION RISQUES• PROBLEMES DE SANTE LIES A L’EXPO• VALEURS D’ACTION• MESURES• DEPISTAGE DES PROBLEMES• INFLUENCE DES CARACT INDIVIDUELLES• PRATIQUES SURES• COND DE SURVEILLANCE DE SANTE
CHARGE PHYSIQUE DE TRAVAILCHARGE PHYSIQUE DE TRAVAIL
POUR UN TRAVAIL CONTINU DE 8H
(ENERGIE/SEC EN WATTS)
•TRES LEGERE: <117 WATTS
•LEGERE: DE 117 A 234 WATTS
•MOYENNE: DE 235 A 360 WATTS
•LOURDE: DE 361 A 468 WATTS
•TRES LOURDE >468 WATTS
ESTIMATIONSESTIMATIONS
• TRAVAIL LEGER (180 W): EX. SECRETARIAT
• TRAVAIL MOYEN (300 W): EX. CONDUITE ENGIN
• TRAVAIL LOURD (410 W): EX. MANUTENTION
• TRAVAIL TRES LOURD (520 W) : EX TERRASSEMENT
EFFETS LIES AU FROIDEFFETS LIES AU FROID
• HYPOTHERMIE-COMA-MORT
• ENGELURES
• FRISSONS
• ENGOURDISSEMENT des EXTREMITES
• FROID
EFFETS LIES AU CHAUDEFFETS LIES AU CHAUD
• SENSATION DE CHALEUR
• COUP DE CHALEUR
• CRAMPE DE CHALEUR
• HYPERTHERMIE
• DESHYDRATATION
• DECES
INFORMATIONS TECHNIQUESINFORMATIONS TECHNIQUES
• ISO 7243 DECRIT INDICE WBGT=WET BULB GLOBE THERMOMETER(FICHE 21)
• ISO 7933 DECRIT LE PREDICTED HEALTH STRAIN A PARTIR DE L’INDICE WBGT ET DE L’HISTOIRE DE L’EXPOSITION=PROGRAMME INFORMATIQUE(FICHE 22)
INFORMATIONS TECHNIQUESINFORMATIONS TECHNIQUES
• NBN EN ISO 9886 ERGONOMIE: EVALUATION DE L’ASTREINTE THERMIQUE PAR DES MESURES PHYSIOLOGIQUES
BIBLIOGRAPHIEBIBLIOGRAPHIE
• BROCHURE : AMBIANCES THERMIQUES (SERIE SOBANE)
• SITE WEB DU SPF EMPLOI:
WWWEMPLOI.BELGIQUE.BE
-INFOS
-LEGISLATION
-BROCHURES
FINFINQUESTIONS?QUESTIONS?