39
1 Construction Sika France Pathologie Fissuration

Fissures

Embed Size (px)

Citation preview

Page 1: Fissures

1

Co

nst

ruct

ion

Sika France

PathologieFissuration

Page 2: Fissures

Co

nst

ruct

ion

2

Sika France

LOCALISATION DE LA PHATOLOGIE

FISSURES DUES AU

TASSEMENT DU BETON

FRAIS

Page 3: Fissures

Co

nst

ruct

ion

3

Sika France

DESCRIPTION DE LA PATHOLOGIE

RESSUAGE ET SEGREGATION

- SE MANIFESTE AVANT LA PRISE

- APPARITION D’UNE PELLICULE D’EAU A LA SURFACE LIBRE HORIZONTALE DU BETON FRAIS

- TASSEMENT PROGRESSIF DU SQUELETTE SOUS L’EFFET DE LA PESANTEUR

- DANS LES CAS EXTREMES, CREATION DE FISSURES OUVERTES AU DROIT DES OBSTACLES QUI S ’OPPOSENT AUX MOUVEMENTS DE TASSEMENT DU BETON (armatures, variations locales d ’épaisseur…)

Page 4: Fissures

Co

nst

ruct

ion

4

Sika France

LOCALISATION DE LA PHATOLOGIE

FISSURES DUES AU RETRAIT

PLASTIQUE

Page 5: Fissures

Co

nst

ruct

ion

5

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT PLASTIQUE - DESSICATION

Page 6: Fissures

Co

nst

ruct

ion

6

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT PLASTIQUE - DESSICATION

SURFACE0.5 à 2 mm d’épaisseur

Page 7: Fissures

Co

nst

ruct

ion

7

Sika France

DESCRIPTION DE LA PATHOLOGIE

RETRAIT PLASTIQUE - DESSICATION

- RETRAIT DU BETON FRAIS OU EN COURS DE PRISE LORSQU’IL EST ENCORE DANS UN ETAT AISEMENT DEFORMABLE (avant et pendant la prise pendant un temps limité)

- RETRAIT D’ORIGINE EXOGENE PAR DESSICCATION (évaporation)

- PRINCIPALEMENT LOCALISE SUR LES PIECES MINCES OU SUR LES GRANDES SURFACES HORIZONTALES EN CONTACT AVEC L’AIR

Page 8: Fissures

Co

nst

ruct

ion

8

Sika France

DESCRIPTION DE LA PATHOLOGIE

RETRAIT PLASTIQUE - DESSICATION FACTEUR AGGRAVANT :

Page 9: Fissures

Co

nst

ruct

ion

9

Sika France

LOCALISATION DE LA PHATOLOGIE

FISSURES DUES AU RETRAIT

THERMIQUE

Page 10: Fissures

Co

nst

ruct

ion

10

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT THERMIQUE

Page 11: Fissures

Co

nst

ruct

ion

11

Sika France

DESCRIPTION DE LA PATHOLOGIE

RETRAIT THERMIQUE

- LA CONTRACTION SE MANIFESTE DANS UN LAPS DE TEMPS VARIANT DE QUELQUES DIZAINES D’HEURES A QUELQUES SEMAINES APRES LA MISE EN ŒUVRE DU BETON

- FISSURES PROFONDES TRAVERSANT LA TOTALITE DE L’EPAISSEUR DU BETON

- PRINCIPALEMENT LOCALISE SUR LES OUVRAGES MASSIFS ET PEU SUR LES PIECES MINCES

- ECHAUFFEMENTS IMPORTANTS (> 70 °C) OCCASIONNANT UNE EXPANSION SUIVIE D’UNE CONTRACTION AU REFROIDISSMENT

Page 12: Fissures

Co

nst

ruct

ion

12

Sika France

LOCALISATION DE LA PATHOLOGIE

FISSURES DUES AU RETRAIT

HYDRAULIQUE

Page 13: Fissures

Co

nst

ruct

ion

13

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT HYDRAULIQUE

Page 14: Fissures

Co

nst

ruct

ion

14

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT HYDRAULIQUE

Page 15: Fissures

Co

nst

ruct

ion

15

Sika France

VISUALISATION DE LA PATHOLOGIE

RETRAIT HYDRAULIQUE

FISSURES SOUVENT BORDEES DE CALCITE (diffusion puis carbonatation de la chaux)

Page 16: Fissures

Co

nst

ruct

ion

16

Sika France

DESCRIPTION DE LA PATHOLOGIE

RETRAIT HYDRAULIQUE

- CE RETRAIT COMMENCE AU DECOFFRAGE, PROGRESSE ENTRE 1 ET 28 JOURS ET DOUBLE EN PASSANT DE 1 MOIS A 3 ANS

- FISSURES INESTHETIQUES QUI S’OUVRENT AVEC LE TEMPS, COMPROMETANT QUE TRES PEU LA RESISTANCE DE L ’OUVRAGE CAR ELLES SONT PEU PROFONDES

- APPARAÎT D’AUTANT PLUS RAPIDEMENT QUE LA PIECE EST MINCE

- RETRAIT LENT DU BETON DURCI PAR PERTE D ’EAU : MIGRATION PAR CAPILLARITE DE L’EAU DES ZONES HUMIDES VERS LES ZONES SECHES (favorisé par lorsque l’humidité relative est faible)

Page 17: Fissures

Co

nst

ruct

ion

17

Sika France

LOCALISATION DE LA PATHOLOGIE

FISSURES DUES A LA

CORROSION DES

ARMATURES

Page 18: Fissures

Co

nst

ruct

ion

18

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

LA CORROSION DES ARMATURES EST SOUVENT LIEE A LA CARBONATATION

Page 19: Fissures

Co

nst

ruct

ion

19

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

Page 20: Fissures

Co

nst

ruct

ion

20

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

Page 21: Fissures

Co

nst

ruct

ion

21

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

Page 22: Fissures

Co

nst

ruct

ion

22

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

Page 23: Fissures

Co

nst

ruct

ion

23

Sika France

VISUALISATION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

Page 24: Fissures

Co

nst

ruct

ion

24

Sika France

DESCRIPTION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES

- LA CORROSION DEBUTE LORSQUE L’HUMIDITE ET L’OXYGENE PARVIENNENT AUX ARMATURES

- DEFAUTS ESTHETIQUES AU DEBUT (TACHE DE ROUILLE) QUI PEUT CONDUIRE A LA RUINE DE L’OUVRAGE QUAND LE PHENOMENE SE GENERALISE

- CAUSES PRINCIPALES : BETON POREUX, RECOUVREMENT INSUFFISANT DES ARMATURES, CURE NEGLIGEE, ENVIRONNEMENT HUMIDE RICHE EN CO2

- NEUTRALISATION PROGRESSIVE DE L’ALCALINITE DU BETON ET POUR UN pH < 9-10, DEPASSIVATION DES ARMATURES : FORMATION DE ROUILLE (l’acier en rouillant augmente son volume de 4 fois environ)

Page 25: Fissures

Co

nst

ruct

ion

25

Sika France

DESCRIPTION DE LA PATHOLOGIE

CARBONATATION - CORROSION DES ARMATURES - FACTEUR AGGRAVANT :

SEL DE DEVERGLACAGE

ENVIRONNEMENT MARIN

Page 26: Fissures

Co

nst

ruct

ion

26

Sika France

LOCALISATION DE LA PATHOLOGIE

FISSURES DUES A LA REACTION

ALCALI-GRANULATS

Page 27: Fissures

Co

nst

ruct

ion

27

Sika France

VISUALISATION DE LA PATHOLOGIE

REACTION ALCALI-GRANULATS

Page 28: Fissures

Co

nst

ruct

ion

28

Sika France

VISUALISATION DE LA PATHOLOGIE

REACTION ALCALI-GRANULATS

Page 29: Fissures

Co

nst

ruct

ion

29

Sika France

VISUALISATION DE LA PATHOLOGIE

REACTION ALCALI-GRANULATS

Gel expansif (2) au contact du

granulat siliceux

Dépôt de cristaux de silicate alcalin

sur le granulat siliceuxGel de

silice

Page 30: Fissures

Co

nst

ruct

ion

30

Sika France

VISUALISATION DE LA PATHOLOGIE

REACTION ALCALI-GRANULATS

Page 31: Fissures

Co

nst

ruct

ion

31

Sika France

DESCRIPTION DE LA PATHOLOGIE

REACTION ALCALI-GRANULATS

- LA FISSURATION (RESEAUX DE FAÏENCAGE) APPARAÎT APRES DES DUREES VARIABLES (DE QUELQUES MOIS A 3 ANS OU PLUS SI L ’ENVIRONNEMENT EVOLUE)

- LA FISSURATION INITIALE INESTHETIQUE CONDUIT PROGRESSIVEMENT A LA BAISSE DES PERFORMANCES DU BETON ET UNE DIMINUTION DE LA DURABILITE. LA DESTRUCTION DE L’OUVRAGE RESTE EXCEPTIONNELLE.

- REACTION ENTRE LES ALCALINS PRESENTS DANS LE BETON ET LES GRANULATS SILICEUX REACTIFS

- FORMATION D’UN GEL EXPANSIF A BASE DE SILICATE DE CALCIUM LORSQUE TROIS CONDITIONS SONT REUNIES : PRESENCE D’ALCALIS SOLUBLES, DE GRANULATS REACTIFS ET D’UNE FORTE HUMIDITE (HR > 80 %).

Page 32: Fissures

Co

nst

ruct

ion

32

Sika France

LOCALISATION DE LA PATHOLOGIE

FISSURES DUES A LA DEFORMATION

SOUS CHARGE

Page 33: Fissures

Co

nst

ruct

ion

33

Sika France

VISUALISATION DE LA PATHOLOGIE

FLUAGE

Page 34: Fissures

Co

nst

ruct

ion

34

Sika France

DESCRIPTION DE LA PATHOLOGIE

FLUAGE

- LA FISSURATION APPARAÎT APRES PLUSIEURS MOIS AVEC DES CONSEQUENCES IMPORTANTES

- LE FLUAGE EST D ’AUTANT PLUS FAIBLE QUE LE BETON A DE PLUS FORTES RESISTANCES MECANIQUES

- LORSQU’UNE CHARGE EST APPLIQUEE SUR LE BETON, IL SE DEFORME LENTEMENT

- LORSQUE LES CONTRAINTES ENGENDREES PAR LE FLUAGE DEVIENNENT EXCESSIVES, LE BETON SE FISSURE. IL EXISTE UN FLUAGE POUR TOUTES SOLLICITATIONS : COMPRESSION, TRACTION, FLEXION, TORSION...

Page 35: Fissures

Co

nst

ruct

ion

35

Sika France

PRESENTATION DE LA PATHOLOGIE

Page 36: Fissures

Co

nst

ruct

ion

36

Sika France

VISUALISATION DE LA PATHOLOGIE

DEFAUT DE RESISTANCES MECANIQUES

Rupture en traction (flexion) d’une poutre survenue à un endroit faible (mauvais

recouvrement de armatures)Rupture en compression d’un poteau survenue à un endroit faible (nid de

cailloux)

Page 37: Fissures

Co

nst

ruct

ion

37

Sika France

VISUALISATION DE LA PATHOLOGIE

GONFLEMENT

Page 38: Fissures

Co

nst

ruct

ion

38

Sika France

VISUALISATION DE LA PATHOLOGIE

GONFLEMENT

Page 39: Fissures

Co

nst

ruct

ion

39

Sika France

DESCRIPTION DE LA PATHOLOGIE

GONFLEMENT

- LA FISSURATION APPARAÎT DES LORS QUE LES CONTRAINTES DEVIENNENT SUPERIEURES A LA RESISTANCE EN TRACTION DU BETON

- LE GONFLEMENT DU BETON PEUT ETRE PRODUIT PAR DES MINERAUX EXPANSIFS (excès de gypse, chaux libre, magnésie), LA REACTION ALCALI-GRANULATS ET UNE AGRESSION DU MILIEU EXTERIEUR (sulfates, gel, corrosion des armatures)

- LES FISSURES DE GONFLEMENT SONT D’ABORD INESTHETIQUES MAIS COMPROMETTENT A TERME LA DURABILITE DE L’OUVRAGE